User-friendly interface: 2 built-in LEDs to view the power and motor operation.
Durable construction: Our product is made with high-quality materials and is designed to withstand harsh environmental conditions.
Easy installation: Our product is easy to install and can be integrated with existing water pump systems.
Multiple tank support: Our product can support multiple water tanks and switch between them as needed.
Operation: The system will automatically monitor the water level in the reservoir tank and overhead tank. If water in reservoir is above minimum level and touches min. level in overhead tank it activates the water pump. To adjust the water level threshold, use the adjustment weight available with float. To activate the water pump manually, switch the system to Auto Manual Mode and press the manual activation button. The built-in LEDs on the control unit indicate power and motor operation. Float switch types and setting All types of electrical float switches are compatible.
Power Rating: Input: 190-220VAC 50-60Hz Output: 190-220VAC 50-60Hz Motor Load: 22A Max.
Maintenance:
- Regularly check the electrical float and ensure that it is securely fixed to the tank.
- Clean the electrical float periodically to remove any buildup or debris.
- Check the wiring connections periodically and ensure that they are secure.
- If the system is not operating correctly, consult the troubleshooting guide provided in this manual.
Troubleshooting: If you experience any issues with the system, consult the troubleshooting guide below:
- Water pump activates frequently:
- If the water pump activates frequently even when the water level is not low, check for leaks or other issues in the water system that may be causing the water level to drop.
- Check Float Switch is working properly or not, also adjust according to instructions
- The water pump does not activate:
- Check the wire connections and ensure that they are secure.
- Check the power supply to ensure that it is switched on.
- Check the water level threshold setting to ensure that it is set correctly.
- The water pump does not shut off:
- Check the Float wiring connections and ensure that they are secure
- Check the electrical float to ensure that it is functioning correctly.
- The water pump activates frequently:
- Check the water level threshold setting and adjust as necessary.
- Check the electrical float to ensure that it is functioning correctly.
- If the above solutions do not resolve the issue, please contact our customer support team for further assistance. If the system is not operating correctly after troubleshooting, contact our customer support team for assistance.